16 research outputs found

    Time resolution of the plastic scintillator strips with matrix photomultiplier readout for J-PET tomograph

    Full text link
    Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the 2 x 5 configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the 2 x 5 matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of \approx 0.170 ns for 15 cm axial field-of-view (AFOV) and \approx 0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.Comment: To be published in Phys. Med. Biol. (26 pages, 17 figures

    Determination of the 3\gamma fraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner

    Get PDF
    Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3\gamma annihilation determined using \gamma-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elemental analysis performed using scanning electron microscop (SEM) equipped with energy-dispersive X-ray spectroscop EDS show high purity of the investigated materials.Comment: 12 pages, 2 figure

    MOLECULAR DIAGNOSTICS IN BIOLOGY AND MEDICINE

    No full text
    W ostatnim dziesięcioleciu rozwój i wdrożenie technik molekularnych zrewolucjonizowało diagnostykę i monitorowanie chorób człowieka. Techniki badań kwasów nukleinowych, takie jak genotypowanie DNA mikroorganizmów, analiza polimorfizmu fragmentów restrykcyjnych (RFLP) i reakcja łańcuchowa polimerazy (PCR) przyczyniają się do stałego postępu w laboratoriach diagnostyki medycznej. Analiza sekwencji amplifikowanych fragmentów DNA umożliwia lepszą identyfikację patogenów, wykrywanie zmutowanych genów a także prognozowanie określonych chorób.In the last decade, the development and application of molecular techniques has revolutionised the diagnosis and monitoring of human diseases. Nucleic acids techniques, such as microbial DNA genotyping, analysis of restriction fragment length polymorphism (RFLP) and polymerase chain reaction (PCR), are making progress in medical diagnostic laboratories. Sequence analysis of amplified DNA allows better identification of pathogen, detection of mutant genes and more accurate prognosis of certain diseases

    Nano-modified non-woven filter fabrics capable of holding viruses

    No full text
    W przypadku występowania zanieczyszczeń powietrza w postaci niebezpiecznych mikroorganizmów, sensownym staje się zastosowanie specjalnych układów filtracyjnych. Dzięki zastosowaniu odpowiednich materiałów, możemy uzyskać systemy filtracyjne w całości biodegradowalne. Poprzez zmodyfikowanie powierzchni filtra nanowłóknami, zmniejsza się ich średnice porów, równocześnie zwiększając jego powierzchnie właściwą. Dzięki temu skuteczność filtracji potrafi wzrosnąć kilkadziesiąt razy. Stosując odpowiednie metody modyfikacji nanowłókien, otrzymujemy układ filtrów selektywnych. Pozwalają one nie tylko na zatrzymywanie zanieczyszczeń oraz mikroorganizmów, ale także na ich eliminację.In case of presence of air pollution with harmful microorganisms it seems reasonable to make use of specialist filtering systems. As a result of using properly selected materials the filtration systems can be 100% biodegradable. Surface modification of the filter with nano-fibres brings reduction in mesh size and increases the specific surface area of the filter. This leads to the increase in filtering efficiency even by several dozen times. The application of proper methods of surface modification allows for creating a system of selective filters, which not only stop pollutants and micro-organisms but also may eliminate them
    corecore